611 industrial way west, eatontown, nj 07724 tel: 732-460- 0212 fax: 732-460-0214 sales@advanced-control.com www.a dvanced-control.com frequency range (min) 18 - 30 ghz minimum output voltage 4 mv flatness vs. frequency (max) 0.5 db notes: maximum input power: +14dbm (3db guardband for +17dbm possible burnout) sensitivity is measured into an open circuit load (>10k ohm). environmental specifications: screening: mil-e-5400, mil-std-202, mil-e-16400 internal visual per mil-std-883, method 2017 operating temp: -55c to +100c temperature cycle: -65c to +100c, 10 cycles storage temp: -65c to +100c humidity: mil-std-202f, m103, cond b optional high-rel screening (ref mil-prf-38534): shock: mil-std-202f, m213, cond b stabilization bake per mil-std-883, method 1008 altitude: mil-std-202f, m105, cond b temperature cycle per mil-std-883, method 1010 vibration : mil-std-202f, m204, cond b constant acceleration per mil-std-883, method 2001 thermal shock: mil-std-202f, m107, cond a burn-in per mil-std-883, method 1015 temperature cycle: mil-std-202f, m105c, cond d leak test per mil-std-883, method 1014 external visual per mil-std-883, method 2009 standard case style c7 (optional case styles ? c63, m61) part number ordering information: ? add desired polarity suffix: ?n? for negativ e, ?p? for positive (ex: actp-11796n) ? add desired case style suffix: ?c7? (ex: actp-11796nc7) ? add ?r? suffix: reverse connector configuration (ex: ac tp-11796nc7r) (sma female input/sma male output) ? add ?-rc? suffix: rohs-compliant (ex: actp-11796nc7 -rc) 0109 actp-1796 high frequency tu nnel detectors
611 industrial way west, eatontown, nj 07724 tel: 732-460- 0212 fax: 732-460-0214 sales@advanced-control.com www.a dvanced-control.com actp-1796 typical data input: -20dbm
|